Revit change face based family to non hosted reddit

Revit change face based family to non hosted reddit. I encountered this issue because in my dimension plan, some walls refuse to allow a dimension to the face of the wall. and produce a non-hosted copy is as follows: Place an instance of the family you want to hack in the drawing area. If you are using Revit the way everyone in the world actually uses Revit; Each discipline has their own model and links to each others - Create face based or non-hosted families. Join Paul F. TIP: uncheck "Always Vertical" and check "Work Plane-Based" in family before nesting. the problem I have with my R2022 family (attached) is that I can't delete that host. Further adjusting and tweaking is still required, but it is often the best option compared to rebuilding content from scratch. not automatically. Ask questions about Revit software, standards, trouble shooting, how to, family creation / modification, or just show off your latest project/model. I would love to place the trench gutter directly onto a Pad. By using Ideate BIMLink to change coordinates data in excel and then import that back into Revit it is possible to change one family type for another family Mar 6, 2023 · Hi - you can get the symbol to change depending on orientation - we used to do this with all our lighting families: However, because in Revit 2023 you can "maintain the annotation orientation" for objects when on sloping ceilings (i. Hence using face hosted or workplane based families for MEP so that they will attach to the face of the ceiling or to a workplane aligned to the underside of the ceiling, rather than embedding into a ceiling. Bam it is gone and you have a non host family. Then open the result family, select the host extrusion and change the thickness to 0. com/ Jan 20, 2009 · I have searched, and I don't think that anyone has asked this question yet. Note: A face-based family is required to host the family on a linked Revit model. You'll see how to convert the hosted family to a face-based family using the Copy/Monitor tool. Being able to switch hosting types, or even change a hosted family to non-hosted one would be extremely helpful. Jun 14, 2018 · You can't change how the family itself relates to the host while working in a project. Then that non hosted family can be nested into a ceiling based, or face based, or floor based family. Oct 28, 2022 · thanks for the reply. Jan 19, 2012 · any luck in converting face based to non-host (or work plane based), manually or automatically, well, even manually getting rid of that host (extrusion) doesn't mean a real non-host (or work plane based), for instance , no Offset parameter Mar 2, 2020 · Nest the non-hosted family into a Generic Model Wall Hosted family template. Jan 30, 2017 · Convert Family from Wall to Face based. Aug 29, 2021 · These instructions (after 10 minutes in the video) show how to convert a face-hosted family into a non-hosted family. I want to change this to a face based family so that it will stay attached to a linked wall if that wall moves. Take this moment to learn how to build families in the future. If a family’s hosting is “Ceiling Based”, you’re usually not allowed to host to linked elements. Ask questions about Revit software Apr 30, 2018 · Hi, I’m trying to insert face based families through dynamo. You need to add these parameters into your host family and then link the parameters by selecting the nested family whilst in the host family and clicking the radio button in the Properties on the side of the screen to create a link between the parameters in the host and nested families. Jul 9, 2019 · Convert a Hosted Family to Face-Based or Non-Hosted Family in Revit | Revit This video shows how to change a hosted family to a type that Revit can monitor. Channel: MEP - Family Creation Sep 7, 2021 · Silly question here. but for some reason the hose reel (either nesting, or copy/paste) was 90°F off and the family stuck into the room. If I recall correctly, the void in the face based family only cuts the first element it touches (it’s host,) and a second void in the family is required to cut any other elements using the cut command, i. The parameters you want to change in the nested families need to be instance parameters. This is it, you created a geometry placeholder which you can load to a non-hosted model and then use it to host other face based families to rotate them any direction. e. . This is how you do it. I have a reference family that i am building off of and this reference family has a nested family placed upright and is hosted to the hosted reference point. For example, use a section if it is hosted to a wall or a floor plan if it is hosted to the floor. This is done by deleting the host. Your Interior Design drawings can use this family and your TM/ Viz software will take it, too. Apr 7, 2014 · In relation to a 'face' based family (probably others as well) what function does the 'Default Elevation' serve? Whilst I obviously understand what the both words mean, there seems to be no relationship between any family created using one of the templates and any arbitary value assigned to the parameter. So in the family environment, if you have an array of 3, you can have a max of 3 when it’s loaded into the project. We can have a face-based family that cut void on any surfac Aug 3, 2023 · A ceiling hosted family will ONLY attach to a ceiling and the ceiling has to exist in your model - it won't work with ceilings in linked files. Face-based families also have two key characteristics that are important to MEP workflows. /r/Revit A place to talk about anything related to Revit. So, if you want to change the offset and keeping the association with its host, set the offset distance by parameter in the family. Save As ‘unhosted’ version of your family; If needed, nest this again into a new, clean family based on whatever category / hosting you want A convoluted process where you copy/monitor the hosted family which creates a face-based version of the family. If I select a single outlet, and activate the "Pick New" option I can rehost it to a vertical face, and all is good. Once the setting has been saved, this option is greyed. 🔰In this video, we will learn how to Convert #Revit Hosted Families to Face Based Family or Non-Hosted Family In the modelling process, i Now the reference is to the centerline of the wall and Revit adds the CL symbol. Since you're doing it in Revit and TM I'd put it in Revit as it's independent objects you'll want to actually see and document rather than a generic sign blank. Problem is the architect's are Level based, ours are all face based so the orientation of the geometry comes in wrong as per the image. Choose Collaborate, I can't exactly recall, but you may need to use face-based light fixture families to host to linked ceilings, and linked surfaces in general. It will make the family bit heavier but should do what you're after. It would be a lot easier to use structural elements that are designed for this type of bespoke positioning out of the box. is it possible? I believe Revit does not like hosted arrayed voids that aren’t already within the family. It seems like you are placing a face-based family, so you should be able to rotate the family from a view that is perpendicular to the face of the element that it is hosted to. 1. I’d recommend changing the hosting to face based, and then using reference planes to host to. Thank you in advance, Drew Aug 10, 2011 · You can change non-hosted to hosted by turning on "Workplane Based" in the family options. I currently have GPOs which are not hosted to anything but I'm starting to think you're better off facebasing it so it's one less thing to lock to a plane (joinery doc). I don't have the desire to re-create the exact same family just to make it face based. Aug 13, 2009 · We also have the same issue, we want to locate furniture and lights on floors and ceilings in linked files so that we don't work directly with the central file (we don't want the responsibility/liability of touching the central file, we don't own it (the central file) and we don't want to go there) and yet we would like to attach elements to the linked surfaces to make it easy for our Dec 17, 2021 · Hello, I am trying to convert this trench gutter from Revit City from a floor-based family to a face-based family, using this guide. I made a plumbing fixture family that was not wall based. Re-constrain and add whatever is missing. ByFace” node, but i can only use surfaces from elements or system-families (like walls). If you try to make more arrays, the family won’t cut like you want it to. the same dimension pasted between views should not change references. Back in 2011 I posted about some related workflows, including the necessary steps to get System family elements in a normal Component family: Save an In-Place Family as an RFA for use in another project Create a Component Family with Category set to Walls (or other system family category) Jan 10, 2018 · Hi. Then you will get the option to Place on Face or Place on Workplane. I know Revit default is wall based for most elec stuff which means you need to create new families to do the same thing. Nov 21, 2018 · Use the copy monitor trick to convert it to face based family. Aug 17, 2023 · Last step, Now change the family type to Site, this way you can ensure its hidden and does not mix with any other family types. Aug 9, 2011 · About the best you can do is nest the hosted (assuming it's only face based) into the non-hosted and re-link parameters. Or use a work plane based family in stead of face based. Jun 20, 2023 · I am referring to do in the the family environment, not in the project, change the host definition of the family, the non hosted family can be hosted in a face and a work plane but it does not behave the same as a Face based family Nov 29, 2023 · Changing wall-based families to face-based families as there is no direct way to convert them in Revit. All families should be built to be non-hosted (90% rule). Especially when downloading manufacturer-created families that might be set up incorrectly. What gray blob? Are you trying to tell if a family in a project is face based? Or in the family editor itself? In a project a family will have a button to place the family on a face if it’s face based. You can insert multiple ones at the same time; Save the file and close it; Jul 26, 2016 · Recently there was a need for a custom piece of Revit family casework which was inadvertently made using a wall-based family template. Face based was a rushed concept from AutoDesk Sep 19, 2017 · I think each option has it's usefulness, it just depends on the family. I noticed there is no face-hosted plumbing template, so i use a generic face hosted model and mad that into a plumbing family. How to change a floor based skyline window to face based window. Delete the facr plane and uncheck the workplane based family checkbox in the properties. If you want to cut host element automatically at the moment of face-based void placement, you have to cut the host element first. I came across this post about switching lighting families from wall hosted to face-based and with a little tweak, made it work for casework. I have a question regarding the host of the family in revit. Apr 30, 2012 · Is it possible to change a family from Face based to level based. Saveas the family and link it into the project you originally wanted it in, your family is now level hosted. Mar 19, 2014 · So the highly-intuitive process (sarcasm anyone?) of taking a family that is built in a hosted template such as face-based, wall-based, ceiling-based, etc. I think if there was just an option within the family editor that we could adjust it would be best. They can then be nested into a wall hosted family. If you are using Revit the way Autodesk thinks it works; One single model shared by all disciplines (somehow) - Hosted families will work. but I have a family that is not hosted (blank for the host). You have to essentially model in your own ceilings to host to, hence why you’re able to host it to a new project. Difficult and time consuming but could be done, if you were really good with Revit. The family editor needs to assume what will be the host and everything else needs to be set according to that. This is undesirable behavior. There are multiple family categories in Revit which can be set to both wall-based or face-based. Open up the family you need to convert to This is a great example of family management. There has to be a straight forward relationship between the family and the project. Jun 1, 2017 · Select the elements from the face based families (geometry, reference planes, parametric dimensions), CRTL+C, and CTRL+V align to view on the non-host family. mepguy. And I made a fake If it's 2d CAD output, then I'd design the sign in CAD, then create a Revit family from it. Best of both worlds. looks like it's the only workaround, i have a dream - i can convert cleanly all hosted families to non-hosted except face-based for void cutting purpose Apr 27, 2011 · I know how to convert a wall or ceiling based family to a face based family. I use face-based for handles so you can rotate vertical or horizontal orientation. If I create a face-based receptacle that will always be hosted on a wall (or something vertical), I'd like it to default to the vertical face, not a non-vertical face. Access my courses at:https://www. for some reason when i try to place the same nested family on my own hosted reference point, it does not place upright, but instead horizontally. I was wondering if there was a way to convert a ceiling based family, like an air terminal, to a face based familt for use with a linked model. The best thing to do is create face based families for all your electrical objects. But yeah Aug 28, 2021 · 🔰In this video, we will learn how to Convert Revit Hosted Families to Face Based Family or Non-Hosted Family In the modelling process, it is very common to receive some families that are Wall based or Ceiling based but actually, its is annoying sometimes but don’t worry we can convert them very easily Arch needs to be very careful with how they edit those walls or else it ruins all the hosting. it now works!), we changed all our lighting symbols to be type based instead: ended up making more sense. Also when levels change, hosted elements don't reflect the change correctly, and if you have multiple of the same elements at varying heights its a pain to have to go through each one and change the values, this is something I'm doing at the moment, and wouldn't need to with a level based family. When you load it to the Revit project and place on any surface, it cuts host element automatically. For face based, you might need to double nest to rotate the 90 degrees: nest the loose into a face based sticking out of the surface, then stick that family to the sill reference plane of the face based, and link relevant parameters through both May 21, 2023 · #shorts Join Paul F. If we have a family that needs a host, we have converted them to face based families (instead of walls) using the copy/monitor work around.   Jul 26, 2017 · I forgot to mention that when you move a face based equipment off the host, it will become non-host. I got it to work using the “FamilyInstance. Also Revit just doesnt like when you do that. Dec 11, 2023 · Copymonitor the family from the linked model when you have the host model open (this will convert to face) Edit the copyminotored family. Members Online potatoartist2 /r/Revit A place to talk about anything related to Revit. Feb 1, 2012 · Question: After placing your hosted Air Terminals on the face of the linked ceiling, what does "Host" read under its Properties? I cannot get a face-based fixture to host to a linked ceiling in this project, period. Jan 12, 2016 · But you can use the Cut tool and select host element, then void, and then you will have a cut there. Is there a way to do this? I know you can go from a wall hosted to face hosted, just not sure if I can go from non-hosted to face host.  I need to understand this when nesting such families. If in the family editor, the family type options will have a Host Type parameter that should say Face if it’s face hosted. If it is already modelled as upright when placed on floor you might want to also set it to "Always Vertical" so that it doesnt rotate 90 degrees when placed on a wall. Aug 22, 2021 · . Then each of these families gets their own separate reference plane in the group. Nov 7, 2020 · Revit Beginners Must know in MEP How To Convert Diffuser Hosted Ceiling Based Family to Non-Hosted Nest that loose family into a wall based, and link parameters. I can go into a Section and designate the ceiling face as the current Work Plane and then place the fixtures. How to create a light fixture family that is face based instead of wall based. The nested family would have the controls for the angle and the container family would be face hosted to the roof. It seems that reference planes don’t Yes. But the problem arises when I copied the shower cabin to the other floors, some of them directly hosted to the floor level which is 200 mm rise, but some hosted to the level which is 0 mm elevation. I have downloaded a shower cabin family in revit and inserted into my multi story building. Feb 8, 2019 · This would be a game-changer in family creation. I've copy monitored architect's electrical fittings into our model and done an automatic mapping with our fixtures. Revit currently doesn't support converting a wall-based Dec 28, 2019 · We explore the idea of converting a faced based family to a Level-Based (Non-Hosted Family) Load your hosted family into that special family and host it onto the object that it wants (Wall, Floor, Ceiling, Roof) Work with parameters as needed, link them through etc if needed. Another important distinction that I learned from Aaron's work is to use reference planes for when things do need to be hosted. This is also good practice, because ceilings are easily deleted by accident even in your host model, and will delete hosted elements with them without warning; face-based families are able to exist independently are less subject to accidental tampering. Aubin for an in-depth discussion in this video, Convert a hosted family to face-based or non-hosted family, part of Revit: Tips, Tricks, and Troubleshooting. If I select two or more outlets, even if they are in the same family, the option to host to the vertical face disappears. What i want to achieve is to use reference planes to do the same (in other words: I would like to use a reference plane as a host for my face-based families). (Quarantine Day 66)Today I am going to show you something about the void in the face-based family. You can save the face-based family as an RFA file. iwqrvr vixvyok xpeuu zkq dvclf qez gdgsnxr jbtjx omcjgfnrx zuursu